DDC-231 12V Delay Controller with Beep
Product parameters:
Working voltage: DC12V (normal working voltage DC10V-16V)
Signal source: DC4V~20V (usual power supply positive trigger, button, PNP sensor, PLC signal, etc.)
Output capability: It can control devices within 30v5A or within 220v5A
Quiescent current: 20mA, working current: 50mA
Service life: more than 100,000 times;
Working temperature: -40~85 °C;
Net weight: about 26g
Size: 64.2mm*34.8mm*18.5mm
Features:
Voltage input anti-reverse circuit, worry-free wiring. Signal input optocoupler isolation, strong anti-interference ability. Set the parameter to power off permanent memory. Powerful flash MCU online programming function, according to user needs can contact manufacturers to customize the required functions
DDC-331 12V Delay Controller
Description:
Working voltage: DC12V (normal working voltage DC10V-16V)
Source: DC4V~20V (usual power supply positive trigger, button, PNP sensor, PLC signal, etc.)
Output capability: It can control devices within 30v5A or within 220v5A
Quiescent current: 20mA, working current: 50mA
Service life: more than 100,000 times;
Working temperature: -40~85 °C;
Net weight: about 26g
Size: 64.2mm*34.8mm*18.5mm
Features:
Voltage input anti-reverse circuit, worry-free wiring. Signal input optocoupler isolation, strong anti-interference ability. Set the parameter to power off permanent memory.
Function introduction:
P-1: The signal triggers the relay to pull in. When the time is up, the relay is disconnected during the delay.
A: Invalid trigger again B: Re-trigger re-clocking C: Trigger relay reset again to stop timing
P-2: The signal trigger start timing time T1, the time is up to the relay pull-in time T2 is disconnected (reset)
A: Invalid trigger again B: Re-trigger re-clocking C: Start delay without triggering power-on
P-3: Cycling: Turn on T1, disconnect T2, infinite loop. For T1 and T2, the time is adjustable; if a parameter is turned ON or OFF, it can be turned on or the power is turned on.
A: The relay is turned on immediately after power-on. B: The relay is turned off and then turned on after power-on.
P-4: There is signal, the relay is closed, the suction is kept, the signal disappears, the timing starts, the time is up, the relay is disconnected, during the delay, the signal is given again, the delay is cancelled, the relay is kept, the signal disappears, and the time is re-timed.
DDC-332 12V Delay Controller with Beep
Description:
Working voltage: DC12V (normal operating voltage DC10V-16V)
Source: DC4V ~ 20V (positive trigger common power button, PNP sensors, PLC signals, etc.)
Output capability: You can control the DC or AC 220v5A within 30v5A within
Quiescent Current: 20mA,
Working current: 50mA
Life: more than 10 million times;
Working temperature: -40 ~ 85`C;
Features:
Anti-reverse voltage input circuit, worry-free wiring. Signal input optocoupler isolation, anti-interference ability.
Set the parameters of power and permanent memory. Powerful flash MCU online programming capabilities, according to user needs can contact the manufacturers to customize the functionality.
S1: power on, press S1 2 seconds to enter mode selection menu, press S1, choose P-1 ~ P-4 mode.
S2: OK / Shift key: Press to adjust the position of the LED is blinking, which LED is blinking, S3 to adjust the value of digital tube flicker.
Until you press S2, the digital is no longer flashing.
S3: digital display flashes, S3 adjustment digits from 0-9 successively changed. Normal digital tube display, S3 to adjust the position of the decimal point, the decimal point in bits 0-999 minutes; in 10 bit from 0 to 99.9 seconds; no decimal point indicates 0-999 seconds.
Model Description:
P-1: triggering signal is received, the relay is turned on, the timer expires, the relay off.
A1: During the delay trigger again invalid
A2: During re-timing delay trigger again
A3: Delay trigger again during termination timing relay reset
P-2: triggering signal is received, X start time, the end of counting relay, Y start time, the end of counting the relay off
P-3: Cycle Switch Mode
A1: After power relay is turned on, the end of the timing off, an infinite loop.
A2: After power relay is off, the timing turned end, an infinite loop.
DDC-431 12V Delay Controller
User`s manual:
5V Micro USB time delay relay 4 button 3 digit digital tube
First of all, thank you for purchasing our relay delay control board. The powerful interface is clear and simple, powerful, with one-button emergency stop function (STOP button), with reverse connection protection, reverse connection without burning, power-off memory. Increased sleep mode. After enabling, there is no operation within 5 minutes, the display is automatically turned off, and any button wakes up! Different OP, CL, LOP parameters can be set. These parameters are independent of each other, and save the setting parameters to automatically save power and save functions, etc. demand!
Product manual:
Working voltage: DC6V-DC30V (wide voltage anti-connection protection)
Trigger signal source: high-level trigger DC 3.0V?24V signal ground and system ground to improve the system`s anti-interference ability can also short-circuit the ground
Output capacity: controllable DC 30V/10A or AC 250V/10A equipment
Product size: 64mm*35mm*19.3mm
Mounting hole: diameter 3mm
Working temperature: -40 ° C ~ 85 ° C
Operating mode:
P1 mode: After the signal is triggered, the relay turns on the OP time, then turns off; in the OP time, the following operation
P1.1: The signal is triggered again.
P1.2: Signal triggers re-timed again
P1.3: The signal triggers reset again, the relay is disconnected, and the timing is stopped.
P-2: Give the trigger signal, after the relay turns off the CL time, the relay turns on the OP time. After the timing is completed, the relay is turned off.
P3.1: Give the trigger signal, after the relay turns on the OP time, the relay turns off the CL time, then loops the above action, the signal is given again in the cycle, the relay is disconnected, the timing is stopped; the number of cycles (LOP) can be set
P3.2: No trigger signal is required after power-on, the relay turns on OP time, the relay turns off CL time, and the above actions are cycled; the number of cycles (LOP) can be set
P-4: Signal hold function If there is a trigger signal, the timing is cleared, the relay remains on; when the signal disappears, the relay is turned off after timing the OP; during the timing, there is a signal, and the timing is cleared.
Relay enable mode:
ON : The relay is allowed to conduct during the OP conduction time.
OFF : The relay is prohibited from being turned on and is always off.
Short press the STOP button on the main interface to switch between ON and OFF. The current state will flash, then return to the main interface. This function is the emergency stop function, one button to open and close the relay.
Sleep mode (long press the stop button to view the current mode)
C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display, the program runs normally.
O-d normal mode: the digital tube is always on display
Press and hold the STOP button for 2 seconds and then release to switch the C-P and O-d states. The current state will flash and then return to the main interface.
Timing range:
How to choose the timing range
After setting the parameter value in the mode selection interface, press the STOP button to select the timing range.
XXX. Decimal point is in one place, timing range: 1 second to 999 seconds
XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds
X.X.X. The decimal point is fully illuminated, the timing range is from 1 minute to 999 minutes.
For example, if you want to set the OP to 3.2 seconds, move the decimal point to ten digits, and the digital tube displays 03.2.
Parameter description: OP on time, CL off time, LOP cycle number 1-999 times, "---" stands for infinite loop
These parameters are independent of each other, but each mode shares these parameters. For example, when the on-time OP is set to 5 seconds in P1.1, the user wants to switch to the P1.2 mode, then when entering the P1.2 setting corresponding parameters, the OP also Will be 5 seconds
Displaying 000 on the main interface and pressing the SET button will display OPL, LOP and corresponding time XXX
If only OP in the mode, such as mode P1.1, P1.2, P1.3 time, then short press SET button will only display OP and corresponding time
If the mode has OP, CL, LOP such as mode P3.1, P3.2 short press SET button will display OP and corresponding time, CL and corresponding time, LOP and corresponding times
After setting the mode, it is very convenient to view the parameters set in the current mode by pressing the SET button on the main interface.
How to set parameters:
First determine the working mode of the relay
According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), then enter the main interface "press and hold the SET button for 2 seconds and then release" to enter the mode selection. Interface, select the mode to be set P1.1~P-4 by short pressing the UP and DOWN buttons.
After selecting the mode to be set (for example, P3.2), press the SET button to set the corresponding parameter. At this time, the parameter to be set will flash OP ON time, CL OFF time, LOP cycle number ¡°---¡± means unlimited. The secondary cycle, through the UP, DOWN to adjust the parameter value, support long press (rapid increase or decrease) and short press (increase or decrease 1 unit); after setting the parameter value, select the decimal point position by short pressing the STOP button, select Timing range (corresponding time 0.1 seconds to 999 minutes); short press the SET button to set the next parameter of the current mode, the process is the same as above
After setting the parameters of the selected mode, press and hold the SET button for 2 seconds to release, the currently set mode will flash, then return to the main interface and set the parameters successfully.
Main interface: ¡°000¡± (no decimal point) is displayed when the relay is not working, and the decimal point is clear when the relay is working.
Mode selection interface: long press SET button to enter, after setting is completed, long press SET button to exit, return to the main interface